Mainvilliers WWTP: 19.7% Less Polymer, Drier Cake

Home 9 Case Studies and Results 9 Mainvilliers WWTP: 19.7% Less Polymer, Drier Cake
Key results
19.7% less polymer
€12,316 projected yearly saving
10-month projected payback

Case Study from HydroFLOW France

Centrifuge polymer reduction at Mainvilliers

Centrifuge polymer reduction was the aim when AQUALTER evaluated HydroFLOW® for sludge dewatering at the Mainvilliers wastewater treatment plant, which serves Chartres Métropole. Polymer is a constant cost in mechanical dewatering, and cutting it risks poorer flocculation and wetter cake. The site’s three centrifuges allowed a treated line to be compared with an untreated one. One HydroFLOW® i190 was tested at two positions, and the upstream position on the 140 mm PVC line was chosen. Polymer use fell by 19.7%, and at equal settings the treated cake was 20.68% dry against 18.31%, with centrate suspended solids halved.

The Challenge

  • Centrifuge polymer reduction was needed to cut a constant dewatering cost
  • Reducing polymer can compromise sludge flocculation and cake dryness
  • Centrate quality had to stay low in total suspended solids
  • Untreated cake was damp and putty-like


The Solution

  • Unit tested: one HydroFLOW® i190
  • Installation position: 140 mm PVC line upstream of the polymer pump
  • Positions tested: two on the centrifuge line, with the upstream one selected
  • Comparison: treated centrifuge 2 against untreated centrifuge 1 at matched settings

For centrifuge polymer reduction without losing cake quality, the i190 was tried at two points on the centrifuge line. The upstream position on the 140 mm PVC pipe performed better and became the preferred configuration. Treated and untreated centrifuges were then run at equal settings, so cake dryness and centrate quality could be compared directly.

Key Outcomes

R

19.7% less polymer

R

Centrate solids halved, 80 to 40 mg/L

R

Drier cake: 20.68% vs 18.31%

R

Three P150 units bought

Independent Verification

All results in this study were measured and verified by third-party facilities managers and technical staff.

Summary

One HydroFLOW® i190 cut polymer use by 19.7% at Mainvilliers, with a projected saving of €12,316 a year and a ten-month payback. At equal settings the treated centrifuge produced drier, granular cake, 20.68% against 18.31%, and centrate with half the suspended solids and lower COD. The clearest sign of the result is what the operator did next: Chartres Métropole bought three HydroFLOW® P150 units in May 2021.

Ready to see more?

Ready to explore sustainable water treatment?

Get in touch to find out how HydroFLOW® can work for you.

© 2026 Hydropath Technology Ltd. All rights reserved