Cement Plant: Daily Nozzle Cleaning Eliminated

Home 9 Case Studies and Results 9 Cement Plant: Daily Nozzle Cleaning Eliminated
Key results
100% nozzle cleaning eliminated
24 spray nozzles protected
1 year maintenance-free

Cement plant nozzle scale on a high-pressure spray system

Cement plant nozzle scale meant a plant in the Middle East was cleaning between four and eight spray nozzles every day. Hard water and extreme heat accelerated scale formation, the cartridge filters ahead of the nozzles were clogging too, and the system ran at 45 to 60 bar, so every blocked nozzle mattered. In 2009 one HydroFLOW® C120 was fitted to the nozzle supply line after the cartridge filters. Scale stopped forming, all 24 nozzles stayed clear and the filters stopped clogging, ending the daily cleaning routine. The 2009 installation is still referenced today.

The Challenges

  • Cement plant nozzle scale meant 4 to 8 spray nozzles were cleaned every day
  • Cartridge filters ahead of the nozzles were clogging with scale
  • Hard water was accelerating scale formation
  • Extreme heat made scaling conditions worse still
  • The system ran at 45 to 60 bar, so blockages had real consequences

The Solution

  • Unit installed: one HydroFLOW® C120
  • Installation point: nozzle supply line, after the cartridge filters
  • Installed: 2009
  • System: 24 spray nozzles at 45 to 60 bar
  • Water: hard, in extreme heat

The unit was fitted to the nozzle supply line after the cartridge filters, treating the water on its way to all 24 nozzles. The signal disrupts the conditions that bond scale to surfaces. With the nozzles and the filters staying clear at 45 to 60 bar, cement plant nozzle scale stopped being a daily maintenance job.

Key Outcomes

R

All 24 spray nozzles stayed clear of blockage

R

Cartridge filters no longer clogged or seized

R

No nozzle cleaning over a 1-year test

R

Second production line later fitted

Independent Verification

All results in this study were measured and verified by third-party facilities managers and technical staff.

Summary

One C120 ended a daily nozzle cleaning routine and kept all 24 nozzles clear. Hard water plus heat plus pressure is the worst combination for nozzle scaling, and this plant had all three. The cartridge filters, which had been clogging with the same scale, stopped needing attention at the same time: two maintenance items removed by one installation point.

Ready to see more?

Ready to explore sustainable water treatment?

Get in touch to find out how HydroFLOW® can work for you.

© 2026 Hydropath Technology Ltd. All rights reserved