Comano: Legionella Under 10 CFU/L for Seven Months

Home 9 Case Studies and Results 9 Comano: Legionella Under 10 CFU/L for Seven Months
Key results
All samples below 10 CFU/L
Seven months within limits
Visibly cleaner system

Case Study from HydroFLOW Italy

Hotel Legionella control at Grand Hotel Terme di Comano

Hotel Legionella control kept failing at Grand Hotel Terme di Comano, a 55-room spa hotel over four floors. Legionella periodically reached 10³ to 10⁴ CFU/L, chlorine and high-temperature sanitisation gave only temporary relief, and biofilm in the pipework kept reseeding the system. One HydroFLOW® C100 was installed on the main incoming supply and two P60 units on the hot-water manifolds after the boilers, within a six month programme that included thermal shock and purging. After a brief spike as organic material released from the pipework, certified testing found Legionella below 10 CFU/L in every sample, and levels were still compliant seven months after the last thermal shock.

The Challenge

  • Hotel Legionella control kept failing as contamination returned after each sanitisation
  • Legionella periodically reached 10³ to 10⁴ CFU/L
  • Chlorine and high-temperature sanitisation gave only a temporary reduction
  • Persistent biofilm remained within the pipework
  • The 55-room hotel spans four floors, making system-wide control harder

Hotel tap jet breaker blocked by biofilm before and clean after HydroFLOW, Grand Hotel Terme di Comano Legionella control

The Solution

  • Units installed: one HydroFLOW® C100 and two HydroFLOW® P60
  • Installation point: C100 on the main incoming supply, P60s on the hot-water manifolds
  • Trial: six month programme, including thermal shock and system purging
  • Previous treatment: chlorine and high-temperature sanitisation

Hotel Legionella control was approached as a whole-system programme, treating the incoming water and both hot-water delivery manifolds while thermal shock and purging ran alongside. Levels spiked initially as accumulated organic material released from the pipework. Certified June testing then found Legionella below 10 CFU/L in every sample, and the plumber reported cleaner boilers, pipes, filters and shower heads.

Key Outcomes

R

Certified June testing reported Legionella below 10 CFU/L in every sample

R

The plumber reported cleaner boilers, pipes, filters and shower heads

R

The October update reported compliant levels seven months after the last thermal shock

R

A temporary spike showed accumulated organic material releasing from the pipework

Independent Verification

All results in this study were measured and verified by third-party facilities managers and technical staff.

Summary

Certified testing found Legionella below 10 CFU/L in every sample, and the October update reported compliant levels seven months after the last thermal shock. The initial spike is the honest detail in this post: biofilm coming off the pipe shows up in the samples before it disappears. Seven months compliant is the figure a hotel's water safety plan can use.